Individual Respiratory Protection Devices for Nuclear Industry
Gas mask for emergency-recovery works AVI
TU 2568-036-05795731-00
![]() |
- radioactive aerosols up to 500 DOA pers on NRB-99
- vapors of radioactive iodine inorganic and organic compounds
- organic vapors, acid gases and vapors, poison gases
Completeness:
- panoramic mask PPM-88 (PM-88)
- filtering-absorbing system (box AVI + replaceable filtering element)
- Temperature of application -40 to +40 °С.
Technical Characteristics
| Characteristic | Gas mask AVI |
|---|---|
| Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than | 118 |
| Penetrability factor on oil mist, %, not more than | 0.1 |
| Time of protective effect, minutes, not less than: | |
|
Iodine: 1. at concentration (500-1000) Bk/dm3 2. at concentration (0.5-1.0) Bk/dm3 |
1. 360 2. |
|
Benzene: 1. at concentration 10 g/m3 2. at concentration 1.0 g/m3 |
1. 35 2. |
|
Sulfur dioxide: 1. at concentration 8.6 g/m3 2. at concentration 0.2 g/m3 |
1. 15 2. |
| Weight, not more than: | |
| gas mask/ breathing mask | 850 |
| filtering-absorbing system | 300 |
| Warranty shelf life, years, not less than | 5 |
High efficient breathing mask RV
TU 2568-040-05795731-00
![]() |
Completeness:
- panoramic mask PPM-88 (PM-88)
- filtrating system (filtering element of fine cleaning + replaceable filtering element)
- Temperature of application -40 to +40 °С.
Technical Characteristics
| Characteristic | Breathing mask RV |
|---|---|
| Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than | 108 |
| Penetrability factor on oil mist, %, not more than | 0.001 |
| Weight, not more than: | |
| gas mask/breathing mask | 800 |
| filtering-absorbing system | 250 |
| Warranty shelf life, years, not less than | 3 |
Breathing mask RPA-GP, AVI mark
TU 6-00-05795731-326-00
![]() |
- radioactive aerosols up to 20 DOA pers on NRB-99
- vapors of radioactive iodine inorganic and organic compounds, gaseous and vaporous harmful agents (not more than 5 norms of maximum concentration limit)
- aerosols of 3 and 4 hazard classes (not more than 200 maximum concentration limits)
- aerosols of 1 and 2 hazards classes (not more than 20 maximum concentration limits)
Completeness:
- half-mask (rubber with a knitted obturator, or silicone without a knitted obturator)
- two filtering-absorbing cartridges (replaceable filters with impregnated coal fabric)
- head-band
Technical Characteristics
| Characteristic | Gas mask RPA-GP |
|---|---|
| Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than | 40 |
| Penetrability factor on oil mist, %, not more than | 0.8 |
| Time of protective effect, minutes, not less than: | |
|
Iodine: 1. at concentration (500-1000) Bk/dm3 2. at concentration (0.5-1.0) Bk/dm3 |
1. 2. 360 |
|
Benzene: 1. at concentration 10 g/m3 2. at concentration 1.0 g/m3 |
1. 2. 50 |
|
Sulfur dioxide: 1. at concentration 8.6 g/m3 2. at concentration 0.2 g/m3 |
1. 2. 40 |
| Weight, not more than: | |
| gas mask/ breathing mask | 250 |
| filtering-absorbing system | |
| Warranty shelf life, years, not less than | 3 |
Breathing mask «KAMA-2000GP», AVI mark
TU 6-00-05795731-328-99
![]() |
- radioactive aerosols up to 20 DOA pers on NRB-99
- vapors of radioactive iodine inorganic and organic compounds, gaseous and vaporous harmful agents (not more than 5 norms of maximum concentration limit)
- aerosols of 3 and 4 hazard classes (at concentration not more than 100 mg/m3)
Completeness:
- half-mask (consists of absorbing and filtering materials, outer coating is made of nonwoven thermal bound material)
- frame
- exhalation valve
- nasal clamp
- head-band
Technical Characteristics
| Characteristic | Gas mask KAMA2000GP |
|---|---|
| Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than | 93 |
| Penetrability factor on oil mist, %, not more than | 0.8 |
| Time of protective effect, minutes, not less than: | |
|
Iodine: 1. at concentration (500-1000) Bk/dm3 2. at concentration (0.5-1.0) Bk/dm3 |
1. 2. 360 |
|
Benzene: 1. at concentration 10 g/m3 2. at concentration 1.0 g/m3 |
1. 2. 15 |
|
Sulfur dioxide: 1. at concentration 8.6 g/m3 2. at concentration 0.2 g/m3 |
1. 2. 10 |
| Weight, not more than: | |
| gas mask/breathing mask | 60 |
| filtering-absorbing system | |
| Warranty shelf life, years, not less than | 3 |
Order Form