Individual Respiratory Protection Devices for Nuclear Industry


Gas mask for emergency-recovery works AVI


TU 2568-036-05795731-00

Gas mask for emergency-recovery works AVI
Designed for protection of human respiratory apparatus, face and eyes (at oxygen volume content in the air not less than 17% and total content of deleterious substances not more than 500 values of maximum concentration limit) against:

  • radioactive aerosols up to 500 DOA pers on NRB-99
  • vapors of radioactive iodine inorganic and organic compounds
  • organic vapors, acid gases and vapors, poison gases

Completeness:

  • panoramic mask PPM-88 (PM-88)
  • filtering-absorbing system (box AVI + replaceable filtering element)
  • Temperature of application -40 to +40 °С.

Technical Characteristics

Characteristic Gas mask AVI
Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than 118
Penetrability factor on oil mist, %, not more than 0.1
Time of protective effect, minutes, not less than:
Iodine:
1. at concentration (500-1000) Bk/dm3
2. at concentration (0.5-1.0) Bk/dm3

1. 360
2. –
Benzene:
1. at concentration 10 g/m3
2. at concentration 1.0 g/m3

1. 35
2. –
Sulfur dioxide:
1. at concentration 8.6 g/m3
2. at concentration 0.2 g/m3

1. 15
2. –
Weight, not more than:
gas mask/ breathing mask 850
filtering-absorbing system 300
Warranty shelf life, years, not less than 5

High efficient breathing mask RV


TU 2568-040-05795731-00

High efficient breathing mask RV
Designed for protection of human respiratory apparatus, face and eyes (at oxygen volume content in the air not less than 17%) against radioactive aerosols up to 500 DOA pers on NRB-99.

Completeness:

  • panoramic mask PPM-88 (PM-88)
  • filtrating system (filtering element of fine cleaning + replaceable filtering element)
  • Temperature of application -40 to +40 °С.

Technical Characteristics

Characteristic Breathing mask RV
Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than 108
Penetrability factor on oil mist, %, not more than 0.001
Weight, not more than:
gas mask/breathing mask 800
filtering-absorbing system 250
Warranty shelf life, years, not less than 3

Breathing mask RPA-GP, AVI mark


TU 6-00-05795731-326-00

Breathing mask RPA-GP, AVI mark
The breathing mask is designed for protection of human respiratory apparatus (at oxygen volume content not less than 17%) against:

  • radioactive aerosols up to 20 DOA pers on NRB-99
  • vapors of radioactive iodine inorganic and organic compounds, gaseous and vaporous harmful agents (not more than 5 norms of maximum concentration limit)
  • aerosols of 3 and 4 hazard classes (not more than 200 maximum concentration limits)
  • aerosols of 1 and 2 hazards classes (not more than 20 maximum concentration limits)

Completeness:

  • half-mask (rubber with a knitted obturator, or silicone without a knitted obturator)
  • two filtering-absorbing cartridges (replaceable filters with impregnated coal fabric)
  • head-band

Technical Characteristics

Characteristic Gas mask RPA-GP
Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than 40
Penetrability factor on oil mist, %, not more than 0.8
Time of protective effect, minutes, not less than:
Iodine:
1. at concentration (500-1000) Bk/dm3
2. at concentration (0.5-1.0) Bk/dm3
1. –
2. 360
Benzene:
1. at concentration 10 g/m3
2. at concentration 1.0 g/m3
1. –
2. 50
Sulfur dioxide:
1. at concentration 8.6 g/m3
2. at concentration 0.2 g/m3
1. –
2. 40
Weight, not more than:
gas mask/ breathing mask 250
filtering-absorbing system
Warranty shelf life, years, not less than 3

Breathing mask «KAMA-2000GP», AVI mark


TU 6-00-05795731-328-99

Breathing mask «KAMA-2000GP», AVI mark
The breathing mask is designed for protection of of human respiratory apparatus (at oxygen volume content not less than 17%) against:

  • radioactive aerosols up to 20 DOA pers on NRB-99
  • vapors of radioactive iodine inorganic and organic compounds, gaseous and vaporous harmful agents (not more than 5 norms of maximum concentration limit)
  • aerosols of 3 and 4 hazard classes (at concentration not more than 100 mg/m3)

Completeness:

  • half-mask (consists of absorbing and filtering materials, outer coating is made of nonwoven thermal bound material)
  • frame
  • exhalation valve
  • nasal clamp
  • head-band

Technical Characteristics

Characteristic Gas mask KAMA2000GP
Resistance to continuos air flow at volume rate 30dm3/min, PA, not more than 93
Penetrability factor on oil mist, %, not more than 0.8
Time of protective effect, minutes, not less than:
Iodine:
1. at concentration (500-1000) Bk/dm3
2. at concentration (0.5-1.0) Bk/dm3
1. –
2. 360
Benzene:
1. at concentration 10 g/m3
2. at concentration 1.0 g/m3
1. –
2. 15
Sulfur dioxide:
1. at concentration 8.6 g/m3
2. at concentration 0.2 g/m3
1. –
2. 10
Weight, not more than:
gas mask/breathing mask 60
filtering-absorbing system
Warranty shelf life, years, not less than 3

Order Form


To order right now please fill in the order form. Our managers will answer all your questions:

Name:
Phone/fax number (with code):
E-mail:
Required information and notes:

Мы предлагаем комплексно решить проблему обеспечения чистой питьевой водой

Мы являемся одним из основных поставщиков СИЗОД для министерства обороны и МЧС


Casio G-Shock Наручные часы Casio. Сравнения цен в магазинах epoha.su аудит охраны труда и безопасности gpbexpert.ru
PLC «Sorbent» Russia, 614113, Perm, Galperina St., 6. Tel: +7 (342) 258-65-54, +7 (342) 258-65-56. Fax: (342) 283-65-10, 283-68-90. E-mail: info@sorbent.su

When reprinting the information, the reference to the web-site is obligatory



Site map

Created by the reaktive studio

info@sorbent.su